Mandatory Non-Residential Planning and Design

 

[aembed:http://www.youtube.com/watch?v=e458fpuz5mU]

5.106.1 Storm water pollution prevention plan

5.106.4 Bicycle parking and changing rooms.

5.106.4.1 Short-term bicycle parking. 5% within 200’ of entrance

5.106.4.2 Long-term bicycle parking. 5% of parking capacity

5.106.5.2 Designated parking. 8% for any combination of low-emitting, fuel-efficient, and carpool/van pool vehicles

Energy Efficiency

5.201.1 Scope. The California Energy Commission will continue to adopt mandatory building standards

Water Efficiency and Conservation

5.303.1 Sub meters

– 5.303.1.1 Buildings over 50,000 sq ft.

– 5.303.1.2 Excess consumption. >1000 gal/day

5.303.2: 20% Water savings

5.303.4 20% Wastewater reduction

5.304.1 Water budget.

Conforms to local or DWR landscape ordinance

5.304.2 Outdoor potable water use

Sub meters for landscaped between 1000 and 5000 sq ft

5.304.3 Irrigation design

Weather-or soil moisture-based Irrigation controllers for landscape between 1000 and 2500 square feet

Material Conservation and Resource Efficiency

5.407.2 Moisture control

5.407.2.1 Sprinklers. Prevent spray on structure

5.407.2.2 Entries and openings. Prevent water intrusion into buildings

5.408.3 Construction waste reduction of at least 50%. Recycle or salvage for reuse

5.408.4 Excavated soil and land clearing debris. Reuse or recycled

5.410.1 Recycling by occupants.

5.410.2 Commissioning. Buildings =10,000 sq. ft.

5.503.1 Fireplaces. Install only direct-vent sealed-combustion type

5.504.3 Covering of duct openings and protection of mechanical equipment during construction

Environmental Quality

5.504.4 Finish material pollutant control Comply with VOC limits:

Adhesives, sealants, caulks, Paints, coatings

Carpet systems. Green Label Plus program or other listed standards

5.504.4.5 Composite wood products. Meet formaldehyde

limits referenced

5.504.4.6 Resilient flooring systems

Comply with VOC-emission limits referenced for 50% of flooring

504.5.3 Filters. MERV 8

5.504.7 Environmental tobacco smoke control. No smoking within 25’ of entries, air intakes and operable windows

5.507.4 Acoustical control

Min. Sound Transmission Coefficient (STC) values for

exterior wall and roof-ceiling assemblies (50),

exterior windows (30),

interior wall and floor-ceiling assemblies (40)

5.508.1 Ozone depletion and global warming reductions

CFCs: CFC free equipment

Halons: Halon free fire suppression equipment.  8