Nov 262012
 

Non-Residential Chapter 5

 

Planning  and  Design

5.106.1 Stormwater pollution prevention.

Require BMP’s instead of designed plan

 

5.106.4 Bicycle parking.  

Delete reference to UC Policy on Sustainable Practices

 

5.106.4 Designated parking.

Marking: “CLEAN AIR/VANPOOL/EV”

instead of “CLEAN AIR VEHICLE”

 

5.106.8 Light pollution reduction.

Now Mandatory (previously – Voluntary)

IESNA TM‐15‐11 2011, TABLE 5.106.8 for allowable BUG ratings

 

5.106.10 Grading and paving.

Provides examples such as swales and french drains

 

 

Water Efficiency and Conservation

 

5.303.1 Buildings in excess of 50,000 square feet Option for sub‐metering of cooling towers, evaporative coolers and boilers

 

5.303.2 20% reduction in indoor water use.  

Include residential lavatory faucets in table and clarification for showerheads.

 

5.303.2.1 Multiple showerheads serving one shower Controlled by a single valve

 

Material Conservation and Resource Efficiency

 

5.408 Construction waste reduction, disposal and recycling

– New options: Waste management company

– New option: Waste stream reduction (2 Ib/sq. ft.)

– Exception for contaminated excavated soil and land clearing debris from being re‐used or recycled

 

5.410.1 Commissioning. Exceptions for:

– Dry warehouses

– Conditioned accessory under 10,000 sq ft within dry warehouses

– Initial tenant improvements under 10,000 sq ft

 


Environmental Quality

 

5.504 Pollutant control

Temporary ventilation.

Use MERV 8 filter if HVAC is used for ventilation during construction

Carpet systems. Change to one of the referenced standards

Resilient flooring systems. Change to referenced standard

Filters. Added exception  or return air and return with pre-filtered outside air (ductless HP)

 

5.507.4 Acoustical control

STC : Sound transmission class

‐ OITC : Outdoor‐indoor sound transmission class

– CNEL : Community noise equivalent level

‐    Distance to airports and freeways are removed

‐ Envelope: STC 50 or OITC 40,

Windows: STC 40 as 30) or OITC 30 for:

o  Within 65 CNEL noise contour of an airport

o Within 65 CNEL or Ldb noise contour of a freeway, expressway, railroad, industrial or other sources determined by the General Plan

‐ Buildings exposed to 65 dB where noise contours are not available:

o Envelope: STC 45 or OITC 35,

Windows: STC 40 or OITC 30 ‐ Performance method: provide interior noise environment not exceeding 50 dBA

 


Additions and Alterations to Existing Buildings

 

Division 5.7 – Additions and alterations to existing nonresidential buildings

•July 1, 2012 : 2,000 sq ft additions, $500,000 alterations •2013 Code: 1,000 sq ft additions, $200,000 alterations •New Division 5.7“Additions and alterations to existing nonresidential buildings” (State definitions)

 

Notable differences:

Storm water pollution prevention.

  Applies to additions

–     Bicycle parking.

  If 10 or more parking spaces being generated

Designated parking.

  If 10 or more parking spaces being generated

Grading and paving.

  When drainage path is effected

Irrigation controller.

   Only applied to landscape areas between 1000-2500.

Recycling by occupant.

   Triggered when there is an increase in floor

area of 30% or more in 12 month

Testing  and  adjusting  of  new systems only

    (no commissioning)

 

Appendix

New Appendix A6 – Commissioning standards – Forms ∞