Non Residential Voluntary Tier 2

 

[aembed:http://www.youtube.com/watch?v=HkoUa5PqAsU]

Non-RESIDENTIAL VOLUNTARY TIER 2

  • Exceed T-24 by 30%
  • 12% fuel efficient vehicle parking (SEC A5.106.5.1)
  • Cool roofs (SEC A5.106.11.2)
  • 40% Indoor water savings (SEC A5.303.2.2)
  • 45% Outdoor water savings (SEC A5.304.2)
  • Recycled Content Value of 15% (SEC A5.405.4)
  • 80% C&D waste diversion (SEC A5.408.3.1)
  • 90% of hard floors Low VOC (SEC A5.504.4.7)
  • Low VOC insulation (SEC A5.504.4.8)
  • PLUS 15 electives (planning, water, materials, EQ)

Non-Res. Tier 2

Planning & Design

A5.106.5.1 Designated parking. 12% of total spaces for LEFE and carpool/van pool vehicles

A5.106.11.2 Cool Roof

3 elective measure from Planning & Design

Energy Efficiency

A5.203.1.1 Exceed 2008 California Energy Code by 30%

Water Efficiency and Conservation

A.303.2.1 35% Savings in indoor water use

A5.304.4.2 45% reduction in water use for irrigation

3 elective measure from this division

Material Conservation and Resource Efficiency

A5.405.4 Recycled content. Min 15%

A5.408.3.1 Enhanced Construction Waste Reduction. Min 80%

3 elective measure from this division

Environmental Quality

A5.504.4.7 Resilient flooring systems. Comply with VOC-emission limits for 90% of resilient flooring

A5.504.4.8 Thermal insulation. Comply with VOC-emission limits and no added formaldehyde

3 elective measure from this division

3 additional electives from any division